CONTROLLER OPERATION
Controller Selection
Controller: # of Flashes: Off Time:
POLARIS Eos 1 Approximately 5 seconds
PENTAIR IntelliTouch 1 Approximately 5 seconds
JANDY AquaLink RS (rev K) 2 Approximately 5 seconds
JANDY AquaLink RS (rev L) 3 Approximately 5 seconds
After initialization for both the controller and the LM2, a software connection should have been
made. A valid connection can be verified by observing the menu screen of the controller being used.
If the chlorinator does not appear to have made a connection, try resetting both the LM2 and the
controller.
When connected to a suitable controller the LM2 behaves as a “drone”, responding only to the con-
troller, so NONE of the buttons on the LM2 will function.
Controller Disconnection
If the communication link between the controller and the LM2 is lost, the LM2 will continue opera-
tion as it was before the controller lost connection. The chlorinator will then behave as a “stand
alone” unit until the controller is reconnected or the user changes the settings.
Warning Messages on Controllers
Low Salt
Polaris Eos: Error code flashes “Check Chlorinator” on the screen, as well as displaying a salt level of
2900ppm, indicating that the salt level in the pool should be checked.
Jandy Aqualink RS (REV “K”): displays a salt level of 2900ppm, indicating that the salt level in the
pool should be checked.
Jandy Aqualink RS (REV “L”): displays a salt level of 2900ppm, as well as a “LOW SALT” warning
message, indicating that the salt level in the pool should be checked.
Pentair IntelliTouch: displays a salt level of 2900ppm, as well as a “LOW SALT” warning message,
indicating that the salt level in the pool should be checked.
NOTE: The “Add Salt” light will also be illuminated on the LM2 power pack. Always test the salt
level before adding additional salt.
No Flow
In a genuine ‘No Flow’ situation the LM2 red “No Flow” light will be illuminated on the LM2 power
pack in addition to the following screen displays: