DCM-I : Digitally Controlled Zone Mixer
3
DCM-1 : Digitally Controlled Zone Mixer
8 stereo line inputs, 4 ME-1 inputs plus paging mic, 8 balanced outputs (2 stereo plus 6 mono)
General Description
8 stereo line inputs (1 balanced)
8 balanced line outputs (2 stereo + 6 mono)
4 dedicated ports for optional remote line input modules
4 dedicated ports for optional remote mic
input modules
Mic paging to all zones with fully programmable
override logic
Separate analogue paging mic input with
contact closure zone selection
Separate RJ45 interface for PM Series digital
paging microphones
Supports multiple CDR-1 Remote Controls
(optional) in any wiring configuration
CDR-1 provides local control of source,
level, EQ and group enable
2 x 16 character LCD dot-matrix display
(both DCM-1 and CDR-1)
• 4 definable zone groups
Any line input may have priority in any zone;
operation also configurable per-zone
Code-protected “Installer” mode (both DCM-1
and CDR-1) prevents user access to
configuration menus
Inputs, zones and groups can be named
RS232 interface for control by third-party
control systems
Front-panel LEDs confirm remote access
Optional equaliser modules for Bose
®
, Amina
and Active Audio loudspeakers can be fitted
No PC required
Multiple DCM-1’s may be cascaded for
larger systems
External Music Mute input for interfacing
with emergency systems
Any input (mic or line) may be assigned
as Emergency Input, overriding Music Mute
2U 19” rack-mounting unit
Utility Tool Software Download
Application
Diagram
Input Screen Output Screen System Screen